Wiki source code of Fluvius AMR & MMR (NPS systeem)
Last modified by Bart Verheecke on 2024/05/01 20:16
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | [[image:https://tse1.mm.bing.net/th?id=OIP.6v4kHQq9Mjctbtvsng4IBgHaDs&pid=Api&P=0&w=414&h=206||height="64" width="129"]] | ||
2 | |||
3 | Using our plugin for Fluvius' NPS (Netuser Paid Services), you can gain insight into your consumption and production registered by the digital meter, green energy meter and gas meter via Eniris. | ||
4 | |||
5 | We process standard export 91 & export 95. Currently 92 is also pending. | ||
6 | |||
7 | To this end, Fluvius sends CSV files that arrive on our server every day. | ||
8 | |||
9 | |||
10 | {{video url="https://youtu.be/Lrv76E7Tg6I"/}} | ||
11 | |||
12 | |||
13 | |||
14 | [[image:1648649041398-218.png]] | ||
15 | |||
16 | = = | ||
17 | |||
18 | = **You must conclude a contract between yourself and Fluvius** = | ||
19 | |||
20 | You do this with the following contract: [[attach:2021_NPS_Fluvius_contractaanvraag_NL .docx||target="_blank"]] | ||
21 | |||
22 | It is important that you fill in the following: | ||
23 | |||
24 | |||
25 | [[image:111.png]] | ||
26 | |||
27 | [[image:1673884712001-248.png]] | ||
28 | |||
29 | You must then forward the password & username to info@eniris.be | ||
30 | |||
31 | |||
32 | = **You must conclude a contract between yourself and the end user** = | ||
33 | |||
34 | You do this with the following form: | ||
35 | |||
36 | |||
37 | [[attach:NPS_Fluvius_volmacht_NL.docx||target="_blank"]] | ||
38 | |||
39 | |||
40 | |||
41 | More info: [[https:~~/~~/eniris.be/nl/monitoring-van-een-amr-mmr-en-ymr-meter-fluvius/>>https://eniris.be/nl/monitoring-van-een-amr-mmr-en-ymr-meter-fluvius/]] | ||
42 | |||
43 | More info: [[https:~~/~~/wiki.eniris.be/wiki/publicinformation/download/Integraties/AMR%20%26%20MMR%20%28NPS%20systeem%29/WebHome/nps_export_catalog_NL.pdf?rev=1.1>>https://wiki.eniris.be/wiki/publicinformation/download/Integraties/AMR%20%26%20MMR%20%28NPS%20systeem%29/WebHome/nps_export_catalog_NL.pdf?rev=1.1]] | ||
44 | |||
45 | Other formats: | ||
46 | |||
47 | Export 91: AMR daily original | ||
48 | |||
49 | Export 92: AMR daily update | ||
50 | |||
51 | Export 93: AMR monthly definitive | ||
52 | |||
53 | Export 94: MMR definitive | ||
54 | |||
55 | Export 95: AMR daily consumptions | ||
56 | |||
57 | Export 96: AMR monthly consumptions | ||
58 | |||
59 | |||
60 | [[image:https://chat.eniris.be/file-upload/Dn4yg3o38vDGZKrgj/Clipboard%20-%201%20juni%202022%2008:18.png]] | ||
61 | |||
62 | |||
63 | = **Add to the EMS dashboard** = | ||
64 | |||
65 | |||
66 | Go to: [[https:~~/~~/databeheer.fluvius.be/nps>>https://databeheer.fluvius.be/nps]] | ||
67 | |||
68 | |||
69 | Click on "items" and then on "search": | ||
70 | |||
71 | [[image:1652899844504-647.png]] | ||
72 | |||
73 | |||
74 | Then click on the desired EAN number & check the direction: | ||
75 | |||
76 | [[image:1652899920947-109.png]] | ||
77 | |||
78 | = **Electric consumption and production** = | ||
79 | |||
80 | |||
81 | [[image:1651788869558-589.png]] | ||
82 | |||
83 | **__Actual Power = Active Power - Production - P__** | ||
84 | |||
85 | **Fields:** | ||
86 | |||
87 | ["P_15min_prod"] | ||
88 | |||
89 | **Retention Policy:** | ||
90 | |||
91 | rp_ten_m | ||
92 | |||
93 | **Measurement:** | ||
94 | |||
95 | fluviusQuarter | ||
96 | |||
97 | **Correctionfactor Meter:** | ||
98 | |||
99 | 250 | ||
100 | |||
101 | **Conditions:** | ||
102 | |||
103 | {"eanGsrn":"ABC"} | ||
104 | |||
105 | **InfluxSeries:** | ||
106 | |||
107 | cumulativeSingleField | ||
108 | |||
109 | |||
110 | If the counter processes results on a daily basis: | ||
111 | |||
112 | **Fields:** | ||
113 | |||
114 | ["activeEnergyProduced"] | ||
115 | |||
116 | **Retention Policy:** | ||
117 | |||
118 | rp_six_h | ||
119 | |||
120 | **Measurement:** | ||
121 | |||
122 | fluviusDay | ||
123 | |||
124 | **Correctionfactor Meter:** | ||
125 | |||
126 | 1000 | ||
127 | |||
128 | **Conditions:** | ||
129 | |||
130 | {"eanGsrn":"ABC"} | ||
131 | |||
132 | **InfluxSeries:** | ||
133 | |||
134 | cumulativeSingleField | ||
135 | |||
136 | |||
137 | |||
138 | **__Actual Power = Active Power - Usage - P__** | ||
139 | |||
140 | **Fields:** | ||
141 | |||
142 | ["P_15min_cons"] | ||
143 | |||
144 | **Retention Policy:** | ||
145 | |||
146 | rp_ten_m | ||
147 | |||
148 | **Measurement:** | ||
149 | |||
150 | fluviusQuarter | ||
151 | |||
152 | **Correctionfactor Meter:** | ||
153 | |||
154 | 250 | ||
155 | |||
156 | **Conditions:** | ||
157 | |||
158 | {"eanGsrn":"ABC"} | ||
159 | |||
160 | **InfluxSeries:** | ||
161 | |||
162 | cumulativeSingleField | ||
163 | |||
164 | |||
165 | __**Inductive Reactive power = Unductive reactive power = Q**__ | ||
166 | |||
167 | **Fields:** | ||
168 | |||
169 | ["Q_15min_prod"] | ||
170 | |||
171 | **Retention Policy:** | ||
172 | |||
173 | rp_ten_m | ||
174 | |||
175 | **Measurement:** | ||
176 | |||
177 | fluviusQuarter | ||
178 | |||
179 | **Correctionfactor Meter:** | ||
180 | |||
181 | 250 | ||
182 | |||
183 | **Conditions:** | ||
184 | |||
185 | {"eanGsrn":"ABC"} | ||
186 | |||
187 | **InfluxSeries:** | ||
188 | |||
189 | cumulativeSingleField | ||
190 | |||
191 | |||
192 | __**Capacitive Reactive power = Capacitive reactive power = Q**__ | ||
193 | |||
194 | **Fields:** | ||
195 | |||
196 | ["Q_15min_cons"] | ||
197 | |||
198 | **Retention Policy:** | ||
199 | |||
200 | rp_ten_m | ||
201 | |||
202 | **Measurement:** | ||
203 | |||
204 | fluviusQuarter | ||
205 | |||
206 | **Correctionfactor Meter:** | ||
207 | |||
208 | 250 | ||
209 | |||
210 | **Conditions:** | ||
211 | |||
212 | {"eanGsrn":"ABC"} | ||
213 | |||
214 | **InfluxSeries:** | ||
215 | |||
216 | cumulativeSingleField | ||
217 | |||
218 | |||
219 | (% id="cke_bm_39487S" style="display:none" %)__** **__(%%)__**Note**__ | ||
220 | |||
221 | The green energy meter sends 3 values each time: | ||
222 | |||
223 | |||
224 | [[image:https://encrypted-tbn0.gstatic.com/images?q=tbn:ANd9GcTQAkXBqVMv0_UshkEeN7Zlyy9xzvltvK-_Bg&usqp=CAU||alt="FOTOVOLTAÏSCHE ZONNE-ENERGIE :"]] | ||
225 | |||
226 | |||
227 | P_15min_prod (actief vermogen), Q_15min_cons (capacitief blindvermogen), Q_15min_prod (inductive reactive power) | ||
228 | |||
229 | |||
230 | |||
231 | |||
232 | |||
233 | |||
234 | = **Gasdata** = | ||
235 | |||
236 | |||
237 | For the time being, there are two ways in which gas data is processed: | ||
238 | |||
239 | If hourly gas data is available, there are two fields you can use: | ||
240 | |||
241 | * energyDelta_Wh | ||
242 | * volumeDelta_Nm3 | ||
243 | |||
244 | Both have "gasMetrics" as measurement and can be found in retention policy "rp_one_h". | ||
245 | |||
246 | If gas data is available on a monthly basis, there are two fields you can use: | ||
247 | |||
248 | * absVolume_Nm3 | ||
249 | * gasConversionFactor | ||
250 | |||
251 | Both have "gasMetrics" as measurement and can be found in retention policy "rp_one_h". | ||