Wiki source code of Alfen
Last modified by Tijs on 2023/10/06 18:26
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | {{toc/}} | ||
2 | |||
3 | = **Integrations with the Smart Grid Controller** = | ||
4 | |||
5 | The smart grid controller is an intelligent connection between all your energy devices that takes into account your preferences so that you automatically save maximum energy. It is a personal energy manager for your home or business that takes actions such as real-time adjustments based on renewable energy sources (e.g. PV or wind), dynamic control of charging stations, battery systems, heat pumps, and other energy-consuming devices. | ||
6 | |||
7 | See: [[https:~~/~~/smartgridone.com/>>url:https://smartgridone.com/]] | ||
8 | |||
9 | The smart grid controller supports the control of Alfen charging stations. Communication is via Modbus TCP/IP. | ||
10 | |||
11 | |||
12 | |**Merk**|**Model**|**Type**|**Vermogen (kW)**|**Spanning (V)**|**Communicatieprotocol** | ||
13 | |Alfen|((( | ||
14 | Eve Single S-line | ||
15 | |||
16 | [[image:1668427796506-531.png||height="188" width="72"]] | ||
17 | )))|AC|11|400|OCPP 2.0 | ||
18 | |Alfen|((( | ||
19 | Eve Single Pro-line | ||
20 | |||
21 | [[image:1668427812920-257.png||height="203" width="114"]] | ||
22 | )))|AC|22|400|OCPP 2.0 | ||
23 | |Alfen|((( | ||
24 | Eve Double Pro-line | ||
25 | |||
26 | [[image:1668427826976-478.png||height="217" width="141"]] | ||
27 | )))|AC|44|400|OCPP 2.0 | ||
28 | |Alfen|((( | ||
29 | Twin | ||
30 | |||
31 | [[image:1668427844004-642.png||height="204" width="51"]] | ||
32 | )))|AC|44|400|OCPP 2.0 | ||
33 | |||
34 | = **Documentation** = | ||
35 | |||
36 | |||
37 | Integratie met Alfen ICU EZ: [[attach:Leaflet - ICU EZ.pdf||target="_blank"]] | ||
38 | |||
39 | [[attach:eve single user manual web V2.2 en.pdf||target="_blank"]] | ||
40 | |||
41 | |||
42 | = **Ace service installer bug** = | ||
43 | |||
44 | Ace Service Installer geeft soms de error "Get register range at 50514, count 54 - Error: Illegal data adress". | ||
45 | Deze error komt voor wanneer de laadpaal probeert te communiceren met een meter wanneer deze niet aanwezig is. | ||
46 | |||
47 | Het probleem is dat Ace Service Installer (ASI) foutief deze meter heeft geconfigureerd zonder dat deze instellingen zichtbaar zijn. | ||
48 | |||
49 | [[image:1694436785234-182.png]] | ||
50 | |||
51 | |||
52 | Oplossing: | ||
53 | |||
54 | Selecteer dat de laadpaal met een externe meter communiceert. | ||
55 | ASI ziet dit niet als verandering, dus is de knop "save" disabled. | ||
56 | Selecteer hiervoor een andere laadpaal, op dat moment vraagt ASI toch om de wijzigingen op te slaan en sla dit dan ook op. | ||
57 | Ga terug naar de laadpaal die problemen geeft, en stel de instelling nu goed in (EMS-systeem). | ||
58 | |||