5
6 = **Data connection via API.** =
7
8 Via Eniris Insights we retrieve data from the inverters via API. You must provide us with the following:
9
10 ~> User ID: the user id can be found by clicking on a single installation. In the URL you will see the user id.
11
12 [[image:image-20210930112625-1.png]]
13
14
15 ~> The name of the plant you wish to monitor
16
17 ~> Credentials of your account or guest account (username + password)
18
19
20 **Then request the API key**
21
22 __//Via~://__
23
24 [[https:~~/~~/www.fimer.com/contacts/contact-us/submit-your-inquiry>>https://www.fimer.com/contacts/contact-us/submit-your-inquiry]]
25
26
27 __//Message~://__
28
29 We would like to get access to these installations via the open api:
30
31 NAME BUILDING
32 Entity ID XXXXXXXX
33 MAC XX:XX:XX:XX:XX:XX
34
35 SERIAL XXXXXX-XXX-XXXX
36
37
38 **Local, in parallel with ABB logger:**
39
40 ~* In parallel with the VSN300 via modbus TCP (Modbus TCP server for SCADA integration)
41
42 [[attach:FIMER_VSN300WifiDataLogger_EN_Rev_A_FIMER_VSN300WifiDataLogger_EN_Rev_A.pdf||target="_blank"]]
43
44 [[image:1653954333185-618.png]]
45
46 ~* VSN700-serie in parallel from VSN700-05-XX (Max) en VSN-MGR-MAX
47
48 [[attach:VSN700 Data Logger Product Manual_EN.pdf||target="_blank"]]
49
50 [[image:1653954291914-440.png]]
51
52 [[attach:VSN-MGR-CMML-P1-US Specs.pdf||target="_blank"]]
53
54 [[image:1653954200488-532.png]]
55
56 **Local, without ABB logger:**
57
58 Via the Solar Gateway
59
60
61 = **Solar Gateway** =
62
63 With the **Eniris Solar Gateway** you can read and control ABB inverters. Together with the online platform [[Eniris Insights>>url:https://eniris.nl/nl/monitoring-zonnepanelen/]], you have the option to visualize production data, store measurement data, generate reports for maintenance and financial analysis and manage alarms.
64
65 Both the RS232 and RS485 interface of the ABB inverter are read.
66
67
68 (((
69 **__PVI-AEC-EVO Data Logger__**
70 )))
71
72 [[image:1654160718088-715.png]]
73
74 Can be replaced by the Eniris Solar Gateway
75
76
77
78 A few types
79
80 PVS 100/120:  [[attach:FIMER_PVS-100_120-TL B2 Version_Product manual_EN_RevD.pdf||target="_blank"]]
81
82
83 = **Support** =
84
85
86 |FIMER|PVS-10-TL-SX
87 |FIMER|PVS-10-TL-SY
88 |FIMER|PVS-12.5-TL-SX
89 |FIMER|PVS-12.5-TL-SY
90 |FIMER|PVS-15-TL-SX
91 |FIMER|PVS-15-TL-SY
92 |FIMER|PVS-20-TL-SX
93 |FIMER|PVS-20-TL-SXD
94 |FIMER|PVS-20-TL-SY
95 |FIMER|PVS-30-TL-SX
96 |FIMER|PVS-30-TL-SY
97 |FIMER|PVS-33-TL-SI
98 |FIMER|PVS-33-TL-SX
99 |FIMER|PVS-33-TL-SY
100 |FIMER (ABB)|PVI-10.0-TL-OUTD-* 10kW
101 |FIMER (ABB)|PVI-10.0-TL-OUTD-* 11.5kW
102 |FIMER (ABB)|PVI-12.5.0-TL-OUTD-* 12.5kW
103 |FIMER (ABB)|PVI-12.5.0-TL-OUTD-* 13.8kW
104 |FIMER (ABB)|PVS-100-TL
105 |FIMER (ABB)|PVS-120-TL
106 |FIMER (ABB)|PVS-175-TLX-WIRINGBOX
107 |FIMER (ABB)|PVS-50-TL-/S/SX/SX2 50kW
108 |FIMER (ABB)|PVS-50-TL-/S/SX/SX2 55kW
109 |FIMER (ABB)|PVS-60-TL-/S/SX/SX2 60kW
110 |FIMER (ABB)|PVS-60-TL-/S/SX/SX2 66kW
111 |FIMER (ABB)|REACT2-UNO-3.6-TL
112 |FIMER (ABB)|REACT2-UNO-5.0-TL
113 |FIMER (ABB)|TRIO-20.0-TL-OUTD-*-400 20kWmax
114 |FIMER (ABB)|TRIO-20.0-TL-OUTD-*-400 22kWmax
115 |FIMER (ABB)|TRIO-27.6-TL-OUTD-*-400 27.6kWmax
116 |FIMER (ABB)|TRIO-27.6-TL-OUTD-*-400 30kWmax
117 |FIMER (ABB)|TRIO-5.8-TL-OUTD-*-400
118 |FIMER (ABB)|TRIO-7.5-TL-OUTD-*-400
119 |FIMER (ABB)|TRIO-8.5-TL-OUTD-*-400
120 |FIMER (ABB)|UNO-DM-1.2-TL-PLUS
121 |FIMER (ABB)|UNO-DM-2.0-TL-PLUS-*-JVN-*
122 |FIMER (ABB)|UNO-DM-3.0-TL-PLUS-*-JVN-*
123 |FIMER (ABB)|UNO-DM-3.3-TL-PLUS-*-JVN-*
124 |FIMER (ABB)|UNO-DM-4.0-TL-PLUS-*-JVN-*