Wiki source code of AROS (Riello) - SIRIO K12 - K800 central inverter
Last modified by Wim Verheirstraeten on 2023/10/06 18:36
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | **Communication 1** | ||
2 | |||
3 | |Communication interface|RS485 | ||
4 | |Max. number of devices per bus|49 | ||
5 | |Protocol|ModbusRTU | ||
6 | |Bus speed|1200 bps, 9600 bps, 19200 bps, 38400 bps | ||
7 | |Bus speed default|9600 bps | ||
8 | |Default address|1 | ||
9 | |Alarm monitoring|Yes | ||
10 | |||
11 | **Communication 2** | ||
12 | |||
13 | |(% style="width:457px" %)Communication interface|(% style="width:604px" %)Ethernet | ||
14 | |(% style="width:457px" %)Max. number of devices|(% style="width:604px" %)100 | ||
15 | |(% style="width:457px" %)Protocol|(% style="width:604px" %)ModbusTCP | ||
16 | |(% style="width:457px" %)Port|(% style="width:604px" %)502 | ||
17 | |(% style="width:457px" %)Default address|(% style="width:604px" %)1 | ||
18 | |(% style="width:457px" %)Remote Device Access|(% style="width:604px" %)No | ||
19 | |(% style="width:457px" %)Alarm monitoring|(% style="width:604px" %)Yes | ||
20 | |||
21 | **Measurement values recorded** | ||
22 | |||
23 | |(% style="width:458px" %)ERROR (1,...x)|(% style="width:604px" %)Error (1,...x) | ||
24 | |(% style="width:458px" %)E_TOTAL|(% style="width:604px" %)Energy total | ||
25 | |(% style="width:458px" %)F_AC|(% style="width:604px" %)Grid frequency | ||
26 | |(% style="width:458px" %)I_AC1|(% style="width:604px" %)Current AC phase 1 | ||
27 | |(% style="width:458px" %)I_AC2|(% style="width:604px" %)Current AC phase 2 | ||
28 | |(% style="width:458px" %)I_AC3|(% style="width:604px" %)Current AC phase 3 | ||
29 | |(% style="width:458px" %)I_DC (1,...x)|(% style="width:604px" %)Current DC string (1,...x) | ||
30 | |(% style="width:458px" %)I_DCX_Y|(% style="width:604px" %)Current DC (1,...x).(1,...x) | ||
31 | |(% style="width:458px" %)OT_AC_TOTAL|(% style="width:604px" %)((( | ||
32 | Total operating hours | ||
33 | ))) | ||
34 | |(% style="width:458px" %)P_AC|(% style="width:604px" %)Power AC | ||
35 | |(% style="width:458px" %)P_AC1|(% style="width:604px" %)Power AC phase 1 | ||
36 | |(% style="width:458px" %)P_AC2|(% style="width:604px" %)Power AC phase 2 | ||
37 | |(% style="width:458px" %)P_AC3|(% style="width:604px" %)Power AC phase 3 | ||
38 | |(% style="width:458px" %)P_DC|(% style="width:604px" %)Power DC | ||
39 | |(% style="width:458px" %)Q_AC1|(% style="width:604px" %)Reactive power phase 1 | ||
40 | |(% style="width:458px" %)Q_AC2|(% style="width:604px" %)Reactive power phase 2 | ||
41 | |(% style="width:458px" %)Q_AC3|(% style="width:604px" %)Reactive power phase 3 | ||
42 | |(% style="width:458px" %)STATE (1,...x)|(% style="width:604px" %)Status (1,...x) | ||
43 | |(% style="width:458px" %)T|(% style="width:604px" %)Temperature | ||
44 | |(% style="width:458px" %)U_AC1|(% style="width:604px" %)Voltage AC phase 1 | ||
45 | |(% style="width:458px" %)U_AC2|(% style="width:604px" %)Voltage AC phase 2 | ||
46 | |(% style="width:458px" %)U_AC3|(% style="width:604px" %)Voltage AC phase 3 | ||
47 | |(% style="width:458px" %)U_DC (1,...x)|(% style="width:604px" %)Voltage DC string (1,...x) | ||
48 | |||
49 | **Supported Devices** | ||
50 | |||
51 | Sirio Central Inverters series: | ||
52 | |||
53 | Sirio K12 | ||
54 | |||
55 | Sirio K15 | ||
56 | |||
57 | Sirio K18 | ||
58 | |||
59 | Sirio K25 Series | ||
60 | |||
61 | Sirio K33 Series | ||
62 | |||
63 | Sirio K40 Series | ||
64 | |||
65 | Sirio K64 Series | ||
66 | |||
67 | Sirio K80 Series | ||
68 | |||
69 | Sirio K100 Series | ||
70 | |||
71 | Sirio K200 Series | ||
72 | |||
73 | Sirio K250 Series | ||
74 | |||
75 | Sirio K320 Series | ||
76 | |||
77 | Sirio K330 Series | ||
78 | |||
79 | Sirio K500 Series | ||
80 | |||
81 | Sirio K800 Series | ||
82 | |||
83 |