Communication 1

Communication interfaceRS485
Max. number of devices per bus90
ProtocolModbusRTU
Bus speed19200 bps
Bus speed default19200 bps
Default address247
Alarm monitoringYes

Communication 2

Communication interfaceEthernet
Max. number of devices100
ProtocolModbusTCP
Port502
Default address247
Remote Device AccessNo
Alarm monitoringYes

Measurement values recorded

ERROR (1,...x)Error (1,...x)
E_DAYEnergy generated per day
E_TOTALEnergy total
F_AC1Grid frequency phase 1
F_AC2Grid frequency phase 2
F_AC3Grid frequency phase 3
I_AC1Current AC phase 1
I_AC2Current AC phase 2
I_AC3Current AC phase 3
I_DC (1,...x)Current DC string (1,...x)
P_ACPower AC
P_AC1Power AC phase 1
P_AC2Power AC phase 2
P_AC3Power AC phase 3
P_DC (1,...x)Power DC string (1,...x)
STATE (1,...x)Status (1,...x)
U_AC1Voltage AC phase 1
U_AC2Voltage AC phase 2
U_AC3Voltage AC phase 3
U_DC (1,...x)Voltage DC string (1,...x)