English     Dutch     French     German     Spanish

Fluvius AMR & MMR (NPS systeem)

Modifié par Bart Verheecke le 2024/05/01 20:16

https://tse1.mm.bing.net/th?id=OIP.6v4kHQq9Mjctbtvsng4IBgHaDs&pid=Api&P=0&w=414&h=206

Using our plugin for Fluvius' NPS (Netuser Paid Services), you can gain insight into your consumption and production registered by the digital meter, green energy meter and gas meter via Eniris.

We process standard export 91 & export 95. Currently 92 is also pending.

To this end, Fluvius sends CSV files that arrive on our server every day.

1648649041398-218.png

You must conclude a contract between yourself and Fluvius

You do this with the following contract: 2021_NPS_Fluvius_contractaanvraag_NL .docx

It is important that you fill in the following:

111.png

1673884712001-248.png

You must then forward the password & username to info@eniris.be

You must conclude a contract between yourself and the end user

You do this with the following form:

NPS_Fluvius_volmacht_NL.docx

More info: https://eniris.be/nl/monitoring-van-een-amr-mmr-en-ymr-meter-fluvius/

More info: https://wiki.eniris.be/wiki/publicinformation/download/Integraties/AMR%20%26%20MMR%20%28NPS%20systeem%29/WebHome/nps_export_catalog_NL.pdf?rev=1.1

Other formats:

Export 91: AMR daily original

Export 92: AMR daily update

Export 93: AMR monthly definitive

Export 94: MMR definitive

Export 95: AMR daily consumptions

Export 96: AMR monthly consumptions 

https://chat.eniris.be/file-upload/Dn4yg3o38vDGZKrgj/Clipboard%20-%201%20juni%202022%2008:18.png

Add to the EMS dashboard

Go to: https://databeheer.fluvius.be/nps

Click on "items" and then on "search":

1652899844504-647.png

Then click on the desired EAN number & check the direction:

1652899920947-109.png

Electric consumption and production

1651788869558-589.png

Actual Power = Active Power - Production - P

Fields:

["P_15min_prod"]

Retention Policy:

rp_ten_m

Measurement:

fluviusQuarter

Correctionfactor Meter:

250

Conditions:

{"eanGsrn":"ABC"}

InfluxSeries:

cumulativeSingleField

If the counter processes results on a daily basis:

Fields:

["activeEnergyProduced"]

Retention Policy:

rp_six_h

Measurement:

fluviusDay

Correctionfactor Meter:

1000

Conditions:

{"eanGsrn":"ABC"}

InfluxSeries:

cumulativeSingleField

Actual Power = Active Power - Usage - P

Fields:

["P_15min_cons"]

Retention Policy:

rp_ten_m

Measurement:

fluviusQuarter

Correctionfactor Meter:

250

Conditions:

{"eanGsrn":"ABC"}

InfluxSeries:

cumulativeSingleField

Inductive Reactive power = Unductive reactive power = Q

Fields:

["Q_15min_prod"]

Retention Policy:

rp_ten_m

Measurement:

fluviusQuarter

Correctionfactor Meter:

250

Conditions:

{"eanGsrn":"ABC"}

InfluxSeries:

cumulativeSingleField

Capacitive Reactive power = Capacitive reactive power = Q

Fields:

["Q_15min_cons"]

Retention Policy:

rp_ten_m

Measurement:

fluviusQuarter

Correctionfactor Meter:

250

Conditions:

{"eanGsrn":"ABC"}

InfluxSeries:

cumulativeSingleField

Note

The green energy meter sends 3 values each time:

FOTOVOLTAÏSCHE ZONNE-ENERGIE :

P_15min_prod (actief vermogen), Q_15min_cons (capacitief blindvermogen), Q_15min_prod (inductive reactive power)

Gasdata

For the time being, there are two ways in which gas data is processed:

If hourly gas data is available, there are two fields you can use:

  • energyDelta_Wh
  • volumeDelta_Nm3

Both have "gasMetrics" as measurement and can be found in retention policy "rp_one_h".

If gas data is available on a monthly basis, there are two fields you can use:

  • absVolume_Nm3
  • gasConversionFactor

Both have "gasMetrics" as measurement and can be found in retention policy "rp_one_h".

It is the intention that gas data on a monthly basis will soon also be available under the fields as is customary for an hourly basis.

In this way, the conversion of consumption in nm3 to Wh is not with a fixed calorific value, but is adjusted dynamically.

 

Applications

(c) Eniris, 2024